JCSS/MRA Accredited laboratory


The accreditation body (IA Japan) which operates JCSS is a signatory to the multilateral arrangement of APLAC and ILAC for the mutual recognition of calibration certificates.

Details of Accredited Scope in Calibration
Accreditation No.: JCSS0110
Name of Organization: SATO KEIRYOKI MFG. CO., LTD.
Accredited Laboratory: Calibration Engineering Section, Miyagi Factory
Address of Laboratory: 25-1, Nishi-gaoka, Muratacho, Shibata-gun, Miyagi-pref., 989-1304 JAPAN
Accreditation Scope
Accreditation Criterion
Temperature/Humidity
ISO/IEC 17025:2005
Accreditation Date: December 28, 2007
(initially accredited on May 13, 2002)

Type Range of Calibration
Thermometer with Indicator
(Comparative calibration)
From 0 °C up to 50 °C
More than 50 °C up to 100 °C
More than 100 °C up to 150 °C
More than 150 °C up to 200 °C
Thermometer with indicator
(Comparative calibration)(*1)
From 0 °C up to 60 °C
Thermometer with indicator
(Comparative calibration)(*2)
From 0 °C up to 60 °C
Liquid-in-glass Thermometer 0 °C
More than 0 °C up to 50 °C
More than 50 °C up to 100 °C
More than 100 °C up to 150 °C
More than 150 °C up to 200 °C
(*1) Comparative calibration with cell
(*2) Comparative calibration with temperature testing chambers

Accreditation Date: September 6, 2006
(initially accredited on May 13, 2002)

Type Range of Calibration
Dew Point  Hygrometer Dew point
From -10 °C less than 0 °C
Dew point
From 0 °C up to 20 °C
Dew point from -10 °C less than
0 °C at calibration temperature 23 °C (*3)
Dew point from 0 °C up to
20 °C at calibration temperature 23 °C (*3)
Electronic Hygrometer Relative humidity from 10 % up to
40 % at calibration temperature 23 °C
Relative humidity more than 40 % up to
70 % at calibration temperature 23 °C
Relative humidity more then 70 % up to
90 % at calibration temperature 23 °C
Relative humidity from 30 % up to
40 % at calibration temperature 23 °C (*4)
Relative humidity more than 40 % up to
70 % at calibration temperature 23 °C (*4)
Relative humidity more than 70 % up to
90 % at calibration temperature 23 °C (*4)
Relative humidity from 10 % up to
50 % at calibration temperature 23 °C (*5)
Relative humidity more than 50 % up to
70 % at calibration temperature 23 °C (*5)
Relative humidity more than 70 % up to
90 % at calibration temperature 23 °C (*5)
(*3) Calibration which regards an electronic hygrometer as the hygrometer of a dew point indicator.
(*4) Calibration which regards a dew point hygrometer as the hygrometer of a relative humidity indicator.
(*5) Calibration with temperature and humidity testing chambers


SATO KEIRYOKI MFG. CO., LTD.
Tokyo Japan

Japan Calibration Service System (National Institute of Technology and Evaluation)
http://www.nite.go.jp/asse/jcss/en/index.html

What's JCSS? JCSS Accredited Laboratories Homepage
http://www.jcsslabo.or.jp/index_e.htm

PAGE TOP